Walk-In and Drive-In Climate Chambers for Aging and Environmental Testing

APPLICATION

ASLI’s Walk-In and Drive-In Climate Chambers are essential for testing and aging large products or high-volume samples. They serve industries such as electronics, automotive, aerospace, and communications, simulating a variety of environmental conditions to test the durability and performance of materials and components under extreme temperature and humidity.

SHARE AS
REQUEST A QUOTE
FEATURES

Customizable and Flexible Design: Modular and welded chamber options, adaptable to different sizes and configurations.

Cost-Effective Solutions: Economically designed chambers to suit your budget while delivering high-quality performance.

Easy Installation: Quick move-in and easy assembly, ensuring smooth integration into laboratories.

Precision Control: High-precision linear temperature and humidity control, ensuring accurate and reliable test results.

Durable Construction: Long-lasting materials with customizable finishes tailored to specific laboratory needs.

 

Applicable Testing Standards:

These chambers meet a wide range of industry standards for environmental and aging tests, including:

GB11158: Technical conditions for high-temperature testing room.

GB10589-89: Technical conditions for low-temperature testing room.

GB/T10586-89: Technical conditions for humidity testing room.

GB/T2423.1-2001: Low-temperature testing methods.

GB/T2423.2-2001: High-temperature testing methods.

GB/T2423.3-93: Technical conditions for humidity testing room.

GB/T2423.4-93: Alternating hot and humid test methods.

IEC60068-2-1: Testing methods for low-temperature.

IEC60068-2-2: Testing methods for high-temperature.

GJB150.3: High-temperature test.

GJB150.4: Low-temperature test.

GJB150.9: Humidity test.

GB/T2423.22: Temperature testing methods.

 

For more information, feel free to contact us at:

Email: contact@aslitesting.com

TECHNICAL PARAMETERS

 Model

 THR-volume (low-temperature options : A ~ F)  

 Inner Dimensions(cm)

 Customers designated space size and design 

 Temperature Range

 Low Temperature(A:25℃  B:0℃  C:-20℃ D:-40℃  E:-60℃  F:-70℃) High Temperature 80℃ (80℃ ~150℃ is optional)

 Humidity Range

 20%~98%R.H.(10%-98% R.H. / 5%-98% R.H ,is a special optional condition, need dehumidifier)

Indication Resolution/Distribution

 Uniformity of Temperature & Humidity

 0.1℃; 0.1% R.H/±2.5℃; ±3.5% R.H.

 Control Accuracy of 

Temperature and Humidity

 ±0.5℃; ±2.5% R.H.

 Temperature Rising/Falling 

Velocity

Temperature rising approx. 0.1~3.0°C/min; temperature falling approx.  0.1~1.0°C/min;  ( The Falling Velocity Min.1.0°C /min is a optional)

 Cooling System

 Water cooled

 Protection Devices

 Fuse-free switch, overloading protection switch  for compressor,high and low voltage coolant protection switch, over-humidity & over-temperature protection switch, fuses,  fault warning system, water short storage warning protection

 Optional Accessories

 Slope for cart , Recorder, Water Purifier, Dehumidifier

 Compressor

 French Tecumseh Brand, Germany Bizer Brand

 Power

 AC 380 V(±10%),50/60HZ ,3 phase 5 Lines 

 